Categories

  • ►Commercial
    • Ceiling Exhaust Fans
    • Commercial Ventilation Solutions
    • Dampers
    • Destratification Fans
    • Dryer Booster Fans
    • Energy Recovery Ventilator (ERV)
    • HVLS Fans
    • Hydroponics Fans
    • In-Line Fans
    • Radial Blade Blowers
    • Roof Exhaust Fans
    • Wall Exhaust Fans
  • ►Industrial
    • Centrifugal Blowers & Fans
    • Custom Fans
    • Dampers
    • Destratification Fans
    • HVLS Fans
    • In-Line Fans
    • Industrial Ventilation Solutions
    • Panel & Flange Fans
    • Replacement Impellers
    • Roof Ventilators
    • Tubeaxial Fans
    • Vaneaxial Fans
  • ►OEM
    • AC Fans
    • Axial Fans
    • Cabinet Cooling Fans
    • Centrifugal Fans & Blowers
    • Dampers
    • DC Fans
    • EC Fans
    • In-Line Fans
    • Motorized Impellers
    • OEM & Replacement Impellers
    • OEM Fan Controls
    • OEM Ventilation Solutions
    • Panel & Flange Fans
    • Plenum & Plug Fans
  • ►Residential
    • Air Purifiers
    • Bathroom Ventilation Fans
    • Clothes Dryer Booster Fans
    • Dampers
    • Energy Recovery Ventilators
    • Fan Accessories
    • Fan Controls
    • In-Line Fans
    • Residential Ventilation Solutions
    • Supply & Exhaust Grilles
  • ►Solutions
    • Commercial Ventilation Solutions
    • Industrial Ventilation Solutions
    • OEM Ventilation Solutions
    • Residential Ventilation Solutions
Home / E-CATALOG / TecHome2021 / Energy Recovery Ventilator (ERV)

Energy Recovery Ventilator (ERV)

Description

Continental Fan’s ECO-FLO Energy Recovery Ventilator (ERV) is the all-in-one ventilation solution for new construction and renovation projects. This compact unit is capable of exhausting stale indoor air and supplying fresh filtered air from outside. The ERV core extracts thermal energy from the exhausted air and uses it to either pre-heat or pre-cool the incoming supply air (depending on the season). The ECO-FLO Energy Recovery Ventilator has the added benefit of indoor humidity control, making it ideal for use in both living and working environments.

Design Features of ECO-FLO Energy Recovery Ventilator

  • Extracts stale indoor air
  • Recovers thermal energy from extracted air
  • Supplies fresh, pre-treated air
  • Maintains a comfortable humidity setting
  • Moisture damage prevention
  • Lowers heating and cooling costs throughout the year
  • Low energy demand (7 W)
  • Quiet operation (as low as 0.2 SONES)
  • Multifunctional wireless remote control
  • Plug-&-Play installation
  • Air purification (MERV 5)
  • Rated for continuous operation

ERV vs. HRV: What’s the Difference?

An HRV is designed to supply fresh air to a home, and exhaust stale air from the home. The core of an HRV stores heat from the stale exhaust air in winter, and pre-heats the incoming supply air. In the summer, the core is effectively chilled by the exhausted air, and it pre-cools the incoming supply air.
–    Suitable in colder climates where there is excess humidity during the heating season.

An ERV does everything that an HRV does. In addition, an ERV allows some of the moisture in the more humid air stream to be transferred to the air stream that is dryer. This limits the amount of moisture that is expelled in the winter and that enters during the summer.
–     Suitable for colder climates with no excess humidity during the heating season, as well as for warmer climates with high outdoor humidity in the cooling season.

Not sure whether an energy recovery ventilator is suited for you? See our article: Is an ERV Right for You?

Selection

The criteria to be considered when designing a ventilation network are regional climate and square footage of the building. The climate is the deciding factor whether an ERV or an HRV will be more effective, while the square footage determines how many ventilators will be required.

Airflow Model for Energy Recovery Ventilators

Applications

  • New construction
  • Renovation projects
  • Commercial buildings
  • Offices
  • Homes
  • Apartments

 

A single ECO-FLO ERV can ventilate rooms up to 500 square feet. The fan speed and humidity settings allow for personalized control of each individual room. This makes an ERV suitable for both living and working environments.

Multiple ventilators can operate independently of each other, or they can be wired for primary-secondary operation.

Ventilators can be programmed to operate in unison (the same mode) or in complementary modes (supply and extract). It is recommended that paired units be used to ensure balanced ventilation.

Multiple ECO-FLO ventilators can provide an easy, cost-effective solution for larger buildings undergoing construction or renovation. When arranging a ventilation network, install one unit in each room. For larger rooms, install two or more ventilators. Air flows from one room to another through doors, openings, or hallways, and ensures constant circulation.

Construction Features of ECO-FLO Energy Recovery Ventilator

 

  1. Front Grille with Automatic Shutter
    • Easy access for filter cleaning or replacement
    • Made of high quality snow-white ABS plastic
  2. Reversible Axial Fan
    • Reversible DC ball bearing motor
    • Integrated overheating protection
  3. Telescopic Duct
    • 6” diameter
    • Suitable for walls of varying thickness
  4. Air Filters (MERV 5)
    • Two filters provide air free of dust & pollen
    • Filters are washable for easy maintenance
  5. ERV Core
    • Recovery efficiency of 88% @ 32 F
    • Anti-bacterial treatment
  6. Exterior-Mounted Hood
    • Stainless steel
    • Corrosion proof

Operation Modes of an Energy Recovery Ventilator

Natural Airflow
• Shutter is open; fan does not run.
• Air flows freely through the ventilator and is purified by filters.

Supply Mode
• Ventilator continuously draws in fresh air from outside.
• Air is purified by the filters.

Ventilation Mode
• Ventilator operates in permanent supply or extract mode.
• Synchronized units can provide balanced ventilation.

Regeneration Mode
• Ventilator alternates between supply and exhaust operation every 70 seconds.
• Thermal energy is recovered, and the humidity setting is maintained.

Cycle I
Warm stale air is extracted from the room. It heats and moisturizes the ERV core, transferring up to 88% of the thermal energy. In 70 seconds, the ventilator switches to supply mode.

Cycle II
Fresh outside air flows through the ventilator, absorbing the accumulated moisture and thermal energy in the ERV core and supplying warmed air into the room. In 70 seconds, the ventilator switches back to extraction mode.

Airflow for Energy Recovery Ventilator

Performance for the ECO-FLO Ventilator

MODEL
 
MANUFACTURE
CODE
THERMAL
RECOVERY
TRANSPORTED
AIR TEMP. (F)
POWER
SUPPLY
ECO-FLORA1-50-288%From -4
up to 104
120V/60Hz
1 Phase
SPEED
 
RPM
 
SONES
@3M
WATTS
 
AMPS
 
CFM
 
Low6100.24.500.02412
Med8000.45.000.02621
High14500.57.000.03930

Visit CFM Select to utilize Continental Fan’s state-of-the-art fan selection and quotation platform.

Fan Dimensions for the ECO-FLO Ventilator

  • Select Charts & Diagrams tab below

Download a PDF copy of the ECO-FLO Energy Recovery Ventilator’s Application Guide to learn more about the ERV.

 

 

 

 

 

 

 

 

  • PDF INSTALLATION
Category: TecHome2021.
  • Applications
    • New construction
    • Renovation projects
    • Homes
    • Apartments
    • Offices
    • Commercial buildings

  • Charts / Diagrams

Latest Posts

  • AHR EXPO 2023

  • General Ventilation: How much airflow do we need to ventilate?

  • Mr. Josh Evans – National Sales Manager

  • Mr. Ken Grimes – Retirement

Continental Fan Manufacturing Inc.
1967 Wehrle Drive, Suite 3
Buffalo, New York 14221
Continental Fan Manufacturing Inc.
10212 Freight Drive
Dayton, Ohio 45377
Continental Fan Canada Inc.
12-205 Matheson Boulevard East
Mississauga, Ontario L4Z 3E3

1-800-779-4021 | info@continentalfan.com

Request A Quote
  • Home
  • |
  • E-CATALOG
  • |
  • CFM Select
  • |
  • Dealer Locator
  • |
  • Company
  • |
  • NEWS
  • |
  • Terms & Conditions of Use
  • |
  • Privacy Policy
  • |
© 2023 Continental Fan. All Rights Reserved
Dayton Web Design by Lion And Panda

Request A Quote

    When signing up for e-newsletters, you agree to receive emails from Continental Fan.
This website uses cookies to improve your experience. We'll assume you're ok with this, but you can opt-out if you wish. Cookie settingsACCEPT
Privacy & Cookies Policy

Privacy Overview

This website uses cookies to improve your experience while you navigate through the website. Out of these cookies, the cookies that are categorized as necessary are stored on your browser as they are essential for the working of basic functionalities of the website. We also use third-party cookies that help us analyze and understand how you use this website. These cookies will be stored in your browser only with your consent. You also have the option to opt-out of these cookies. But opting out of some of these cookies may have an effect on your browsing experience.
Necessary
Always Enabled
Necessary cookies are absolutely essential for the website to function properly. This category only includes cookies that ensures basic functionalities and security features of the website. These cookies do not store any personal information.
Non-necessary
Any cookies that may not be particularly necessary for the website to function and is used specifically to collect user personal data via analytics, ads, other embedded contents are termed as non-necessary cookies. It is mandatory to procure user consent prior to running these cookies on your website.
SAVE & ACCEPT