TF Tranquil Bathroom Fans with Light
Description
TF Tranquil Bathroom Fans with light are engineered to provide superior ventilation and efficient performance. The whisper-quiet operation of a TF fan is under 2 sones. The built-in damper prevents a backdraft, keeping tempered air in a home when the fan is not operating. TF Tranquil fans are available in lighted, non-lighted and low-profile versions, suitable for all interiors.
Features and Benefits of TF Tranquil Bathroom Fans with Light
- Whisper-quiet, under 2 sones
- Superior ventilation and efficient performance
- TF80L and TF110L models
- Non-lighted models available
- Durable polymeric resin grille for long life
- 26 GA galvanized steel housing
- Easy installation
- Double hanger mounting brackets adjust up to 24″ span
- Built-in backdraft damper
- Efficient AC motor
- 120V, 60 Hz, single phase operation
- Automatic reset thermal overload protection
- Max 26W GU24 fluorescent light
- ETL listed for use over a tub/shower enclosure with GFCI circuit
- Do NOT use this fan with any solid-state speed control device
- Fits duct sizes 4″ and 6″
Accessories
A full range of accessories is available to suit each application:
| MODEL | TF80L | TF110L |
| CFM @ 0.1" SP | 80 | 110 |
| CFM @ 0.25" SP | 58 | 100 |
| SONES* | 0.4 | 0.9 |
| WATTS | 22.8 | 28.0 |
| POWER RATING (V/Hz) | 120V / 60Hz | 120V / 60 Hz |
| DUCT DIA. (In.) | 4 & 6 | 4 & 6 |
| GRILLE SIZE (In.) | 13 x 14 | 13 x 14 |
HOUSING SIZE
L x W x H (In.) | 11.375 x 10.5 x 7.625 | 11.375 x 10.5 x 7.625 |
| *Sones are rated at 0.1" SP |
Visit CFM Select to utilize Continental Fan’s state-of-the-art fan selection and quotation platform.
Fan Dimensions & Performance Curves
- Select the Charts / Diagrams tab below
How much airflow is required?
HVI recommends ventilation rates based on 8 air changes per hour. For most bathrooms this works out to 1 cfm per square foot of area, with a minimum of 50 cfm.
- A bathroom less than 100 square feet:
- Calculate 1 cfm per square foot of floor area. A minimum of 50 cfm is the required ventilation rate.
- A bathroom larger than 100 square feet:
- To calculate the proper ventilation rate, add the cfm requirement for each fixture; toilet 50 cfm, shower 50 cfm, bathtub 50 cfm, jetted tub 100 cfm. Note: For proper sizing, the static pressure (SP) needs to be calculated.
What is HVI?
HVI, also known as the Home Ventilating Institute, is an independent non-profit organization that certifies fan performance characteristics and provides HVAC guidelines for consumers. Learn more about HVI at HVI.org.
When it comes to choosing the right duct, people often ask, “What is the best duct for bathroom ventilation?” While there isn’t necessarily one absolute right choice, many times the best option is the flexible insulated duct. Learn more in our blog posting: what-is-the-best-duct-for-bathroom-ventilation.
Continental Fan offers a variety of fans from in-line to remote mount to traditional in-ceiling or low profile design to suit any space.